| MRC |
Requirement Statement |
Reply Statement |
| AAGR |
CROSS-SECTIONAL SHAPE STYLE |
A1 ROUND |
| AAJD |
THREAD CLASS |
2B FIRST END |
| AAJD |
THREAD CLASS |
1A SECOND END |
| AAJF |
THREAD DIRECTION |
RIGHT-HAND FIRST END |
| AAJF |
THREAD DIRECTION |
RIGHT-HAND SECOND END |
| AARX |
INSIDE DIAMETER |
1.000 INCHES NOMINAL |
| ABJH |
TEMP RATING |
-40.0 FAHRENHEIT AND 200.0 FAHRENHEIT SINGLE RESPONSE |
| ABKV |
OUTSIDE DIAMETER |
1.563 INCHES NOMINAL |
| ACKH |
MINIMUM INSIDE BENDING RADIUS |
11.000 INCHES |
| AHNC |
CONNECTION STYLE |
C3 SWIVEL NUT FLARE FIRST END |
| AHNC |
CONNECTION STYLE |
D1 FLARED SECOND END |
| AKUU |
END CONNECTION DESIGN |
STRAIGHT FIRST END |
| AKUU |
END CONNECTION DESIGN |
STRAIGHT SECOND END |
| AWLS |
CONNECTION TYPE |
THREADED INTERNAL TUBE FIRST END |
| AWLS |
CONNECTION TYPE |
THREADED EXTERNAL TUBE SECOND END |
| CBBL |
FEATURES PROVIDED |
ELECTROSTATIC DISCHARGE CAPABILITY |
| CMLP |
THREAD QUANTITY PER INCH |
12 FIRST END |
| CMLP |
THREAD QUANTITY PER INCH |
12 SECOND END |
| CQBD |
BURST TEST PRESSURE |
12000.0 POUNDS PER SQUARE INCH |
| CQCS |
LAYER COMPOSITION AND LOCATION |
1ST LAYER SPIRALLY LAID STEEL WIRE AND 2ND LAYER SPIRALLY LAID STEEL WIRE AND 3RD LAYER SPIRALLY LAID STEEL WIRE AND 4TH LAYER SPIRALLY LAID STEEL WIRE AND 5TH LAYER WOVEN FABRIC AND 5TH LAYER BRAIDED FABRIC AND OUTER LAYER MOLDED RUBBER, SYNTHETIC |
| CQJX |
NOMINAL THREAD SIZE |
1.312 INCHES FIRST END |
| CQJX |
NOMINAL THREAD SIZE |
1.312 INCHES SECOND END |
| CQQF |
OPERATING PRESSURE |
3000.0 POUNDS PER SQUARE INCH (PSI) MAXIMUM LOCATION NOT OTHERWISE SPECIFIED |
| CQRB |
SEAT ANGLE |
37.0 DEGREES FIRST END |
| CQRB |
SEAT ANGLE |
37.0 DEGREES SECOND END |
| CRJM |
OUTER COVERING ENVIRONMENTAL PROTECTION |
OIL RESISTANT |
| CRWL |
INSIDE SURFACE CONDITION |
SMOOTH |
| CRXX |
MEASURING METHOD AND LENGTH |
28.500 INCHES NOMINAL OVERALL |
| MEDA |
MEDIA FOR WHICH DESIGNED |
HYDRAULIC FLUID SINGLE RESPONSE |
| SCMP |
ITEM STRUCTURAL COMPOSITION |
MOLDED RUBBER, SYNTHETIC OUTER LAYER |
| SCMP |
ITEM STRUCTURAL COMPOSITION |
SPIRALLY LAID STEEL WIRE FIRST LAYER |
| SCMP |
ITEM STRUCTURAL COMPOSITION |
SPIRALLY LAID STEEL WIRE SECOND LAYER |
| SCMP |
ITEM STRUCTURAL COMPOSITION |
SPIRALLY LAID STEEL WIRE THIRD LAYER |
| SCMP |
ITEM STRUCTURAL COMPOSITION |
SPIRALLY LAID STEEL WIRE FOURTH LAYER |
| SCMP |
ITEM STRUCTURAL COMPOSITION |
WOVEN FABRIC AND BRAIDED FABRIC FIFTH LAYER |
| THSD |
THREAD SERIES DESIGNATOR |
UN FIRST END |
| THSD |
THREAD SERIES DESIGNATOR |
UN SECOND END |